Avaya G700 Maintenance Manual page 156

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:
Table 24. TEST#17 Station (Digital) Audits Test Continued
Error
Test
Code
Result
2
ABORT
3
ABORT
4
ABORT
5
ABORT
6
ABORT
1000
ABORT
1392
ABORT
2000
ABORT
FAIL
PASS
156
Description/ Recommendation
ID request fails, health bit returned from voice terminal is bad.
Make sure voice terminal is connected and repeat test.
If test fails, replace voice terminal and repeat test.
Look for Error Type 769 logged against DIG-LINE and follow the
procedures in the associated footnote. If any additional problems are
found, rerun the test.
Internal system error
Resolve any outstanding Media Module maintenance problems.
Retry the command at 1-minute intervals a maximum of 5 times.
Ringer update aborted due to station being in ready-for-service or
out-of-service state.
This port may have been busied out by system technician.
Look in the Error Log for Error Type 18 (port busied out) for this port.
If this error is present, release the port via release station
Make sure that the terminal is connected.
Retry the command at 1-minute intervals a maximum of 5 times.
System resources required for this test are not available.
This port is currently a TTI port and the test will not execute on it.
Verify that the port is a TTI port using either the display port
command (the display shows that the port is a TTI port) or the list
config command (the display shows a "t" for the port).
If either list config or display port indicate that the port is not a TTI
port, escalate the problem. If both commands indicate that the port is
a TTI port, the abort is correct, and no action is necessary.
Response to the test was not received in the allowable time period.
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
Station Audits passed. This Digital Port Media Module is functioning
properly.
If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
DIG-LINE (Digital Line)
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
2 of 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8700S8300

Table of Contents