The battery feed chip provides power to the telephone equipment, signaling, rotary dial pulsing,
transmission, and balance. This test checks the signaling and switchhook capabilities of the battery
feed chip by terminating the port, applying battery power, and detecting the resulting current.
Table 53. TEST #35 Battery Feed Test
Error
Code
1000
1004
1005
1018
108
Test
Description/Recommendation
Result
ABORT
Necessary system resources could not be allocated to run this test.
Retry the command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
ABORT
System resources are unavailable. The port may be busy with a
valid call. This result is also reported for the system's Music-On-
Hold port when it is off-hook, which it usually is.
Enter display port GGGVSpp to determine the station's extension.
Enter status station extension to determine the service state of
the port.
If the port is in use, wait until the port is idle. Retry the command at
1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
ABORT
A valid call seized the port during the test and aborted the test.
Use the display port GGGVSpp command to determine the station
extension.
Use the status station extension command to determine the
service state of the port.
If the port is in use, wait until the port is idle before testing. Retry the
command at 1-minute intervals no more than 5 times.
If the test continues to abort, escalate the problem.
ABORT
This test was aborted due to a configuration problem. The test is
not applicable for this type of analog port. This error can be ignored.
ABORT
Administration has disabled the test. The default for the Test? field
on the station form is y . Determine why this field has been set to n
on this station (this may be due to the ringing application Test #48,
which can be disturbing to customer or terminal equipment).
To enable the test for a particular station being tested, enter
change station extension.
Change the Test? field on the station form to y .