Xxx-Bd Common Media Modules; Error Log Entries And Test To Clear Values - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:

XXX-BD Common Media Modules

The following list of Media Modules are listed by apparatus code.
Table 91. XXX-BD Common Media Module
Apparatus
Code
MM710
MM711
MM712

Error Log Entries and Test to Clear Values

Table 92. Common Port Media Module Maintenance Error Log Entries
Error
Type
0*
1(a)
18(b)
23(c)
125 (e)
257
257 (g)
267
513 (h)
769 (i)
1281 (k)
1538 (l)
3840 (n)
3999 (o)
260
Name
DS1/E1 Interface - T1, 24 Channel - E1, 32
Channel
Analog Trunk and Line
Digital Line, 24-Port, 2-Wire DCP
Aux
Associated Test
Data
0
Any
0
Media Gateway
removed or SAKI
Sanity Test (#53)
0
busy-out board
GGGVS
0
None
None
65535
Control Channel
Test (#52)
Any
None
0
None
Any
None
4358
None
Ringing Application
Test (#51)
Any
None
Any
None
Any
None
XXX-BD (Common Port Media Module)
Alarm
On/Off
Level
Board
Any
Any
MINOR
ON
WARNING
OFF
WARNING
OFF
MINOR
ON
MINOR
ON
WARNING
ON
MINOR
ON
MINOR
ON
WARNING/
ON
MINOR
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Type
Port
Port
Port
Test to Clear Value
test board GGGVS
sh r 1
release board
GGGVS
test board GGGVS
sh r 20
test board GGGVS
sh
test board GGGVS r
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8700S8300

Table of Contents