4 Media Server Alarms:
Table 24. Alarm #17
Number
Source
Event ID
Alarm Level
Alarm Text Description
Possible Causes
Determining Cause
Resolution
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
17
_WD
24
Major
Watchd high monitor thread is stopping tickling of hw
This if rebooting the server for alarm 23 does not work. This
reboot is done through a Linux system call which may not
succeed. This can occur if Linux kernel semaphore is stuck.
watchd starts a timer prior to calling reboot. If the timer
expires, watchd will stop the HW sanity tickling in hope that
the HW sanity watchdog will reboot the processor (i.e. a hard
reboot).
Go to the Web Interface; choose Diagnostics; View System
Logs; select Watchdog Logs
Clear alarm: From the Web Interface, choose Alarms and
Notification; select the appropriate alarm; choose Clear.
Watch to see if alarm returns.
The server should've rebooted by the time a support person
can analyze the system. A reboot normally fixes problems
with unresponsive software.