Did-Trk (Direct Inward Dial Trunk) - Avaya G700 Maintenance Manual

Gateway/ server or an
Hide thumbs Also See for G700:
Table of Contents

Advertisement

6 Avaya MultiVantage Software-Controlled Maintenance:
Table 11. TEST #36 Port Audit and Update Test Continued
Error
Code
Any

DID-TRK (Direct Inward Dial Trunk)

Table 12. DID-TRK (Direct Inward Dial Trunk)
MO Name (in
Alarm Log)
DID-TRK
DID-TRK
DID-TRK
Note: You must consult local records for the location and designation of the equipment
rack where the G700 is mounted.
A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded
**
by the set options command and that at least 75 percent of the trunks in this trunk group
are alarmed.
Many trunk problems are caused by incorrect settings of parameters on the trunk group
administration form. Settings must be compatible with the local environment and with parameter
settings on the far-end. Refer to Administrator's Guide for Avaya MultiVantage™ Software, 555-233-
506, for information on how to administer trunks. The Application Notes section of that book shows
the correct settings for administrable timers and other parameters on a country-by-country basis.
Direct Inward Dial trunks connect the switch to the CO , and allow outside parties to call directly to an
extension in the system. MM711 supports eight incoming-only ports.
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
NO
The test could not relate the internal ID to the port (no board). This
BOARD
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
If the board was found to be correctly inserted in step 1, issue the
busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
check to see that there is a valid board inserted.
Alarm Level
MAJOR**
MINOR
WARNING
DID-TRK (Direct Inward Dial Trunk)
Initial Command to Run*
test port GGGVSpp l
test port GGGVSpp l
None
2 of 2
Full Name of MO
DID Trunk
DID Trunk
DID Trunk
137

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S8700S8300