6 Avaya MultiVantage Software-Controlled Maintenance:

XXX-BD (Common Port Media Module)

Table 90. XXX-BD (Common Port Media Module)
MO Name (in
Alarm Log)
XXX-BD**
XXX-BD**
XXX-BD**
Note: You must consult local records for the location and designation of the equipment
rack where the G700 is mounted.
Refer to the appropriate Media Module documentation for the correct MO name
**
displayed in this field. It usually ends with BD.
Common Port Media Module Maintenance is a set of common tests used by all the Media Modules
listed in the tables below. The XXX-BD designation is also used on SAT displays when reset board
is entered with an empty Media Module slot, or with a Media Module type that is in conflict with the
actual board type administered for that slot. All Media Module suffixes (B,C, D, and so forth) are
supported by "XXX-BD."
When any of the Common Port Media Modules are physically removed from the backplane, no alarm
will be logged for approximately 11-minutes. (In the case of the MM712 Digital Line, MM720, and
Intuity AUDIX, approximately 21-minutes will elapse before an alarm is logged.) When a Media
Module that has been removed is alarmed, the alarm type is minor and is classified as an on-board
alarm. The time delay permits maintenance activity to be performed without triggering an additional
alarm.
Alarms are logged against only those common port Media Modules on which ports have been
administered. In a heavily loaded system, the interval between the removal of a Common Port Media
Module and the logging of the alarm may be several minutes longer. Suffixes are not shown; for a list
of all Media Modules supported, see the table in Chapter 2. Those that appear in bold type are
documented separately under their own maintenance object name.
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Alarm
Initial Command
Level
to Run *
MAJOR
test board GGGVS
MINOR
test board GGGVS
WARNING
test board GGGVS
XXX-BD (Common Port Media Module)
Full Name of MO
Common Port Media Module
Maintenance
Common Port Media Module
Maintenance
Common Port Media Module
Maintenance