6 Avaya MultiVantage Software-Controlled Maintenance:
This alarm logs approximately 11 minutes after removing the circuit pack and/or the SAKI Sanity
Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack in the same slot as the error indicates.
See note (g).
• (b) Error Type 257 – Transient communication problems between the switch and this circuit pack.
Execute the test board GGGVM command and refer to the repair procedures for the Control
Channel Loop Around Test (#52).
• (c) Error Type 513 – On-board hardware failure. Aux data values correspond to the following
detected errors:
Aux Value
4352
4353
4355
4357
Reset the circuit pack with the busyout board GGGVM and reset board GGGVM
commands. When reset, the circuit pack executes a set of tests to detect the presence of any of the
faults listed above. Detection of one of these errors during initialization causes the circuit pack to
lock-up and appear insane to the system. See the repair procedure in Note ().
• (d) Error Type 769 – The circuit pack detects a program logic error. While no action is required,
this error can lead to other errors against this circuit pack.
• (e) Error Type 1025 – The circuit pack cannot update and read back NPE/NCE memory. This error
can be ignored, but may lead to other errors against this circuit pack.
• (f) Error Type 1291 – The MM720 BRI Media Module notifies maintenance software that it has
detected a parity error while accessing its dynamic RAM (that stores the board's translation
information and downloadable application firmware). Maintenance software resets the circuit pack.
• (g) Error Type 3586 – The SPE software detects an excessive number of up-link messages from the
TN2185 board within a certain time period. To prevent the faulty board from flooding the switch
with data, the switch software takes the board out of service and alarms it. The switch software also
tells the Archangel to ignore up-link messages from the board.
When the board is alarmed due to this error, the switch software periodically puts the board back
in service and tells the Archangel to process up-link messages from the board. If the problem still
exists, the software takes the circuit pack out of service again. If the circuit pack does not exhibit
the problem for a certain time period, then maintenance software resolves the alarm and the
circuit pack is left in service.
• (h) Error Type 3840 – The circuit pack received an inconsistent down-link message (a bad header,
port number, data, subqualifier, or logical link) over the Control Channel.
198
Detected Error
External RAM error
Internal RAM error
ROM Checksum error
Instruction set error