6 Avaya MultiVantage Software-Controlled Maintenance:
Table 70. TEST #143 Minor Alarm Inquiry Test Continued
Error
Code
2100
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL
Minor alarms are often accompanied by slip and misframe alarms
against the board. Trunk alarms and hardware error logs may occur
on the associated trunks.
If the DS1-MM connects to a T1 network facility or to another switch,
do the following:
The performance of the DS1 link between the DS1-MM interface
Media Module and the remote DS1 endpoint is poor. Enter the
list measurement ds1-log GGGVS command to read the error
seconds measurement.
Verify that both endpoints of the DS1 link are administered using
the same signaling mode, framing mode, and line coding.
Contact T1 Network Service or the technician at the remote
switch to diagnose the equipment.
Check the physical connectivity of the DS1-MM interface Media
Modules and the cable.
Replace the local DS1-MM interface Media Module, and repeat
the test.
FAIL
If the DS1-MM connects to a line-side terminating device (for
(cont'd.)
example, a PRI terminal adapter), do the following:
The performance of the DS1 link between the DS1-MM interface
Media Module and the line-side terminating device is very poor.
Enter the list measurement ds1-log GGGVS command to read
the error seconds measurement.
Verify that the switch DS1 and the line-side terminating device
are administered using the same signaling mode, framing mode,
and line coding.
Investigate the maintenance status of the line-side terminating
device. Obtain the error seconds measurement on the
terminating device (if possible). Refer to the 'Line-Side
Terminating Device Operating Manual' for information.
Contact the vendor of the line-side terminating device to
diagnose the equipment.
Check the physical connection of the DS1-MM interface Media
Module to the terminating device, and check the premise
distribution system (or the intra-premise wiring) for physical
connection failures.
Replace the local DS1-MM interface Media Module and repeat
the test.
PASS
No Minor alarm is detected in the DS1-MM Interface Media Module.
MG-DS1 (DS1 Interface Media Module)