Table 13. DID Trunk Error Log Entries
Error
Type
0*
1(a)
1(b)
1(c)
1(d)
15(e)
18
130(f)
257(g)
257(h)
257(i)
257(j)
513(k)
513(l)
769
1537
*Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer
to the appropriate test description and follow the recommended procedures.
**Major alarms may be downgraded to Warning alarms based on the value used in the
set options command.
Notes:
See also the preceding section on trunk problems without errors or alarms.
• (a) This condition occurs when the tone detector times out waiting for digits. Change
wink/immediate-start parameter to wink/immediate-start and rotary/tone-dial parameters.
1) Verify trunk administered wink/immediate-start parameter.
2) Test trunk using BUTT set.
3) Refer problem to CO .
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Aux
Associated Test
Data
0
Any
Any
None
57476
None
57477
None
57483
None
Any
Port Audit Update
(#36)
0
busyout trunk
grp/mbr
None
57472
None
57473
None
57474
None
57475
None
57392
None
57393
None
Any
Port Diagnostic
(#35)
Any
Port Diagnostic
(#35)
DID-TRK (Direct Inward Dial Trunk)
Alarm
On/Off
Level
Board
Any
Any
WRN
OFF
WRN
OFF
WRN
OFF
WRN
OFF
WRN
OFF
WRN
ON
WRN
OFF
WRN
OFF
WRN
OFF
WRN
OFF
MIN/
OFF
WRN **
MIN/
ON
WRN**
MAJ/ MIN/
OFF
WRN**
Test to Clear Value
test port GGGVSpp
sh r 1
release trunk
grp/mbr
test trunk grp/mbr
test port GGGVSpp
r 3
test port GGGVSpp
r 3