6 Avaya MultiVantage Software-Controlled Maintenance:
the station is not in the in-service state. This test does not affect the status of the Message Waiting
lamp.
Table 23. TEST #16 DIG-LINE Station Lamp Updates Test
Error
Test
Code
Result
ABORT
1
ABORT
3
ABORT
1000
ABORT
1392
ABORT
FAIL
PASS
154
Description/ Recommendation
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
This port may have been busied out by system technician.
Look in the Error Log for Error Type 18 (port busied out) for this port.
If this error type is present, then release the port via the release
station <extension> command and run the test again.
Make sure that the terminal is connected.
Retry the command at 1-minute intervals a maximum of 5 times.
Station may be in ready-for-service or out-of-service state.
Use status station command to verify state of station.
Make sure the terminal is connected.
Retry the command at 1-minute intervals a maximum of 5 times.
System resources required to run this test are not available. The port
may be busy with a valid call.
Use display port GGGVSpp to determine the station extension or
attendant number of the port. Use status station or status
attendant to determine the service state of the port. If the port is in
use, wait until the port is idle before testing. Attendants are always in
use (off-hook) if the handset is plugged in and the port is not busied
out.
If the port status is idle, then retry the command at 1-minute intervals
a maximum of 5 times.
This port is currently a TTI port and the test will not execute on it.
Verify that the port is a TTI port using either the display port
command (the display shows that the port is a TTI port) or the list
config command (the display shows a "t" for the port).
If either list config or display port indicates that the port is not a TTI
port, escalate the problem. If both commands indicate that the port is
a TTI port, the abort is correct, and no action is necessary.
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
The message to light all of the station lamps was sent successfully to
the port.
Observe the station lamps being lit when running the test. If all lamps
do not light, the other Digital Line test results may indicate related
problems that do not allow the lamps to light.
Investigate by using other Digital Line port tests, and by examining
the station, wiring, and connections.
DIG-LINE (Digital Line)
Maintenance for S8300/S8700 and G700