9 G700 and Media Module LEDs:
To activate the secondary, the following is similarly done:
Table 113. mgp-001-1(configure)# set syn source sec
mgp-001-1(configure)# sho syn tim
SOURCE
Primary
Secondary
Local
Note: The system uses one clock at a time only: therefore only the secondary is active
and the primary is locked out.
To activate local the following is done:
Table 114. mgp-001-1(configure)# set syn sou local
mgp-001-1(configure)# sho syn tim
SOURCE
Primary
Secondary
Local
To reactivate the primary, the following is done:
Table 115. mgp-001-1(configure)# set syn sou pri
mgp-001-1(configure)# sho syn tim
SOURCE
Primary
Secondary
Local
Note that secondary and local are standby because they are provisioned as fail overs.
If the T1 physical connection were removed, then the secondary becomes active and the primary
reports a failure.
Table 116. mgp-001-1(configure)# sho syn tim
SOURCE
Primary
Secondary
Local
Note that secondary and local are standby because they are provisioned as fail overs.
294
MM
V4
V3
V0
MM
V4
V3
V0
MM
V4
V3
V0
MM
V4
V3
V0
Media Module LEDs
STATUS
Locked Out
Active
Standby
STATUS
Locked Out
Locked Out
Active
STATUS
Active
Standby
Standby
STATUS
Standby
Active
Standby
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
FAILURE
None
None
None
FAILURE
None
None
None
FAILURE
None
None
None
FAILURE
Out of Lock
None
None