6 Avaya MultiVantage Software-Controlled Maintenance:
Table 50. TEST #257 Call State Audit Test
Error
Code
1018
1019
1113
1114
1116
2100
Any
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
ABORT
Maintenance is disable on this trunk.
Enable maintenance by entering "y" in the "Maintenance Tests?" field
on page 2 of the change trunk-group form.
ABORT
An audit is already in progress.
Wait 2 minutes and try again.
ABORT
The signaling link has failed, so the system cannot send any
messages on behalf of this trunk.
Check the results of Test #255 (Signaling Link State Check).
ABORT
The signaling link is in a transitional state.
Retry the command at 1-minute intervals for a maximum of 5 times.
ABORT
The trunk is in an out-of-service ISDN service state.
A call cannot be present if the trunk is in an ISDN out-of-service
state, so a call state audit would be inappropriate. No action
necessary. (Use the status trunk group#/member# command to
investigate the ISDN state of the trunk).
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL
Internal system error
Retry the command at 1-minute intervals for a maximum of 5 times.
PASS
This switch sent a call state auditing message to the far-end switch
to verify the state of the call active on this trunk. If a call state
mismatch is found, then the call will be torn down within two minutes.
If no call was active, then no message was sent.
NO
The test could not relate the internal ID to the port (no board). This
BOARD
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1
GGGVS command to administer the DS1-MM interface if it is not
already administered.
If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then issue
the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the
port.
ISDN-TRK (DS1 ISDN Trunk)