6 Avaya MultiVantage Software-Controlled Maintenance:
Table 63. CO Trunk Errors with No Tests Continued
Error
Type
3329
3585
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Aux
Error Description and Repair Action
Data
57408
Trunk error. No Tip ground detected on outgoing call. This error
occurs when an attempt is made to seize a ground-start CO trunk
for an outgoing call and Tip ground is not detected or the caller
hangs up before Tip ground is detected.
Busyout the affected port, and run a long test. Observe the test
results. If any tests fail, refer to the description of the tests and the
associated error codes. Release the port.
If users continue to report troubles, check for other errors and
make test calls to determine whether the problem should be
referred to the CO . Busyout the affected port, and run a long test. If
Dial Tone Test #0 passes, ignore this error. Release the port.
57424
No loop current on outgoing call. This error occurs on attempt to
seize a loop or ground-start trunk for an outgoing call. An error
occurs if loop current is not detected or the caller hangs up before
it is detected. Busyout the affected port, and run a long test. If CO
Demand Diagnostic Test #3 passes and this error keeps occurring,
refer problems to CO . Release the port.
CO-TRK (Analog CO Trunk)