Table 67. TEST #140 Red Alarm Inquiry Test Continued
Error
Code
1
Maintenance for S8300/S8700 and G700
555-234-101 — Issue 2 — October 2002
Test
Description/ Recommendation
Result
FAIL
The test failed. The DS1-MM interface Media Module detected a
loss of multiframe alarm (LMA). An out of frame condition occurred
on the DS1-MM interface Media Module. The DS1-MM interface
Media Module will transmit a remote multiframe alarm (RMA) to the
remote DS1-MM endpoint until the LMA is retired.
If the DS1-MM connects to a T1 network facility or to another switch,
do the following:
Verify that both endpoints of the DS1 link are administered
using the same signaling mode, framing mode, and line coding.
Contact T1 Network Service or a technician at the far-end
switch to diagnose the remote DS1 endpoint.
Check the physical connectivity of the DS1-MM packs and of
the cable.
Replace the local DS1-MM interface Media Module, and repeat
the test.
If the DS1-MM connects to a line-side terminating device (for
example, a PRI terminal adapter), do the following.
Verify that the switch DS1 and the line-side terminating device
are administered using the same signaling mode, framing
mode, and line coding.
Investigate the maintenance status of the line-side terminating
device. Refer to the 'Line-Side Terminating Device Operating
Manual' for information.
Contact the vendor of the line-side terminating device to
diagnose the equipment.
Check the physical connection of the DS1-MM interface Media
Module to the terminating device, and check the premise
distribution system (or the intra-premise wiring) for physical
connection failures.
Replace the local DS1-MM interface Media Module and repeat
the test.
PASS
No Red alarm is detected on the DS1-MM Interface Media Module.