8Q - 4
VEHICLE THEFT SECURITY - ELECTRICAL DIAGNOSTICS
CENTRAL LOCKING PUMP/SECURITY SYSTEM MODULE SYSTEM UNDERVOLTAGE (CONTINUED)
3.
MEASURE THE VOLTAGE OF THE FUSED B(+) CIRCUIT
Turn the ignition off.
Disconnect the CLP/SSM harness connector.
Note: Check connectors - Clean/repair as necessary.
Turn the ignition on.
Measure the voltage of the Fused B(+) circuit (cavity 2) at the CLP/
SSM C2 harness connector.
Is the voltage above 11 volts?
Yes
>> Go to 4
No
>> Repair the Fused B(+) circuit for high resistance.
Perform VTSS VERIFICATION TEST.
4.
MEASURE THE VOLTAGE OF THE FUSED B(+) CIRCUIT
Measure the voltage of the Fused B(+) circuit (cavity 4) at the CLP/
SSM C2 harness connector.
Is the voltage above 11 volts?
Yes
>> Replace the Central Locking Pump/Security System Mod-
ule. (Refer to 8 - ELECTRICAL/VEHICLE THEFT SECU-
RITY/SENTRY
REMOVAL).
Perform VTSS VERIFICATION TEST.
No
>> Repair the Fused B(+) circuit for high resistance.
Perform VTSS VERIFICATION TEST.