SENTRY KEY REMOTE ENTRY MODULE INTERNAL FAILURE (CONTINUED)
When Monitored and Set Condition
• When Monitored: Continuous.
• Set Condition: If the Sentry Key Remote Entry Module (SKREEM) detects an internal malfunction, the DTC is
set.
NO POWER TO SENTRY KEY REMOTE ENTRY MODULE
SENTRY KEY REMOTE ENTRY MODULE
For a complete Sentry Key Remote Entry (SKREEM) Circuit Diagram, (Refer to 8 - ELECTRICAL/VEHICLE THEFT
SECURITY - SCHEMATICS AND DIAGRAMS).
Diagnostic Test
1.
MEASURE THE VOLTAGE OF THE SKREEM POWER CIRCUIT
Turn the ignition off.
Disconnect the SKREEM harness connector.
Note: Check connectors - Clean/repair as necessary.
Measure the voltage of the Fused B(+) circuit (cavity 18) at the
SKREEM C1 harness connector.
Is the voltage between 12 and 16 volts?
Yes
>> Replace the Sentry Key Remote Entry Module.
Perform SENTRY KEY VERIFICATION TEST.
No
>> System voltage must be between 12 and 16 volts. Repair
the voltage concern as necessary.
Perform SENTRY KEY VERIFICATION TEST.
VEHICLE THEFT SECURITY - ELECTRICAL DIAGNOSTICS 8Q - 37