Internal Air Compressor Filters

This procedure does not apply to systems with an external air source.
Procedure
1.
Power down the system. (See
2.
Removed compressed air hose from the back of the system (if using external air system).
3.
Remove the left panels. (See
A.
Exhaust Muffler
4.
Install the left side panels. (See
5.
Power up the system. (See
FORTUS 360mc/400mc Service Manual
"System Power Down" on
"Panel Removal" on
Replace the pressure-side filters for the Puregas system:
a.
Air filter elements:
• Remove the filter bowls.
• Remove the old filters.
• Install the new filters.
• Reinstall filter bowls.
b.
Exhaust muffler:
• Remove the old exhaust muffler.
• Install the new exhaust muffler.
Figure 8-6: Puregas Filters
"Panel Installation" on
"System Power Up" on
page 5-8.)
page 5-6.)
Intake Filter
Air Filter Elements
page 5-7.)
page 5-9.)
8-9