MIO Board Installation
Tools and Materials Required
• #2 Phillips screwdriver
• Wire cutters
• ESD wrist strap
Procedure
Caution: Wear an ESD wrist strap when working with the MIO
board. If the system has been disconnected from its AC source, the
system frame will not be a proper ground. attach the wrist strap to a
known good ground such as a steel electrical conduit.
1.
Remove the MIO board from the static protection bag.
Caution: Use care not scrape the bottom surface of the board when
positioning the MIO board.
2.
Properly position the MIO board in the system.
3.
Install and tighten the MIO board mounting screws.
4.
Attach all connectors to MIO board.
FORTUS 360mc/400mc Service Manual
Table 5-1: MIO Connectors
Connector Description
Head Cable
AC Board Interface cable
Cassette Interface cable
Oven Thermal Fuse
Oven Thermocouple
Tip Sensor Amplifier
Cone Sensor Switch
Vacuum Switch
Z Homing Switch
Power Supply Cable
MIO Board Connector
J23
J25
J26
J24
J8
P1
J2
J9
J14
J7
5-79