Y Carriage Kapton Barrier

Y Carriage Kapton Barrier Replacement

Tools and Materials Required
• Pliers
• Putty knife
• Safety gloves
Procedure
Warning: The gantry area can be hot. Wear proper protective gear.
1.
Open the top cover.
2.
Place the head in the head maintenance bracket. (See
page
5-13.)
3.
Using a pliers, peel the existing Kapton barrier from the heat shield in the Y carriage.
4.
Gently scrape the remaining adhesive material from the heat shield.
5.
Install a new Kapton barrier.
FORTUS 360mc/400mc Service Manual
Figure 5-11: Kapton Barrier Installation
Kapton Barrier
Installed Here
"Head Maintenance Position" on
Y Carriage Assembly
With Head Removed
5-23