Oven Door Window

Oven Door Window Removal

Tools and Materials Required
• 1/8-inch hex key
• Glass cleaner
• Clean, dry, lint-free towels
Procedure
1.
Power down the system. (See
2.
Carefully remove the eight outer window retaining screws (1/8-inch hex key) while
supporting the window.
3.
Carefully remove the window panel from the door.
8 Retaining Screws
FORTUS 360mc/400mc Service Manual
"System Power Down" on page
Figure 5-4: Fortus 360mc/400mc Oven Door Glass
5-8.)
Door with Window
Panel Removed
5-11