Oven Thermocouple; Oven Thermocouple Removal - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

Oven Thermocouple

Oven Thermocouple Removal

Tools and Materials Required
• T-10 Torx wrench
• Wire cutter
• 11/32-inch hex key
Procedure
1.
Lower the Z stage to the bottom of its travel (Operator control > Move Head/Stage and
the select Move Z Stage to Bottom).
2.
Power down the system. (See
3.
Remove the lower and middle back panel and the upper left side panel. (See
Removal" on page
4.
Disconnect the thermocouple wire from the MIO board.
5.
Cut and remove the cable ties that secure thermocouple wiring.
6.
Remove the cable clamp securing the thermocouple wiring to the underside of the upper
left Z stage end plate.
7.
Remove the four nuts from the left side of the X-Axis Bellows. Slide the bellows to the
right to expose the thermocouple.
8.
Remove the two thermocouple mounting screws (T-10 Torx wrench).
9.
Remove the thermocouple/thermocouple wiring from the system by pulling the wire
and plug into the oven through the oven Z stage seals.
FORTUS 360mc/400mc Service Manual
"System Power Down" on page
5-6.)
Figure 5-62: Oven Thermocouple
5-8.)
"Panel

Oven Thermocouple

(viewed from above)
5-93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortus 400mc

Table of Contents