Cleaning

Cleaning Printer Components

Frequency
Check before every print
Required Tools
Nitrile gloves
Single-use, lint free wipe
IPA
Procedure
Printer components that routinely come into contact with resin should be cleaned with IPA after
each print job. The interior and exterior of the printer may be cleaned with IPA as needed.

Replacing Fan Filters

Frequency
Check after 1 month, repeat as necessary for your print environment.
Required Tools
Replacement Fan Filters (SKUB-00024-000) or (ORIG-00039-S)
Towelette / KimTech Wipe
Warning: Skin contact hazard
Prolonged contact with solvents can cause skin irritation. Do not continue before
putting on protective gloves.