Platen; Platen Removal - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

Platen

Platen Removal

Tools and Materials Required
• 11/16-inch open end wrench
• 1/8-inch hex key
Procedure
Access the platen through the front door of the system.
1.
Position the Z stage to the mid-travel position.
2.
Power down the system. (See
3.
Remove the vacuum screen. (See
4.
Remove the vacuum O-ring from around the edge of the platen and save for reuse.
5.
Remove the vacuum tube fitting from the elbow on the underside of the platen (11/16-
inch open end wrench).
Screw (3X)
Spring
6.
Remove the two tip sensor mount screws from the right underside of the platen (5/32-
inch hex key).
Caution: Use care not to damage the tip sensor when removing the

platen.

7.
Remove the vacuum table mount screws from the underside of the platen (1/8-inch hex
key).
The mount screws are part of a spring assembly. They are located at
the front left, front right, and back center of the platen.
8.
Lift the platen out of the system.
FORTUS 360mc/400mc Service Manual
"System Power Down" on page
"Vacuum Screen Removal" on page
Figure 5-49: Platen Replacement
Washer
5-8.)
Vacuum Tube Fitting
Vacuum Table
Mount Screws
5-71.)
Tip Sensor Mount
5-72