Calibration And Adjustment; Linear Compensation - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

Calibration and Adjustment

Linear Compensation

Tools and Materials Required
• Set of basic service tools
• Dial or digital caliper
Prerequisite Procedures
1.
Power up the system. (See
2.
Make sure the X and Y belt tensions are correct. (See
24.)
3.
Install T16 tip configuration for material being used.
4.
Material type can be any that the system is capable of using for normal modeling.
5.
Stabilize oven temperature for material being used for a minimum of 3 hours.
6.
Perform an XYZ Tip Offset Calibration (see
performing Linear Compensation.
Procedure
A T16 tip configuration for the material being used must be installed
to for this procedure.
If system is to be calibrated in metric mode, all dimensional values
will automatically be converted to millimeter (mm).
1.
Build the linear compensation part.
A.
B.
FORTUS 360mc/400mc Service Manual
"System Power Down/Power Up" on page
Reset the PPU Values.
• Select
Maintenance > Administration > Field
Service (Password) > Machine Configuration >
Linear Compensation >
RstPPUs<E> (90XX,45XX).
• PPU values will be reset to defaults of 9000, 4500.
Build the appropriate PPU part.
• Select
Maintenance > Administration > Field
Service (Password) > Service Jobs to Build.
• Choose the appropriate PPU part for the material being used.
"XY Gantry Belt Tension" on page 6-
"XYZ Tip Offset" on page
5-8.)
6-6) before
10-33