Gantry Cooling Fans Installation
Tools and Materials Required
• Replacement cable ties
• 7/64-inch hex key
Procedure
1.
Position the fan and guard.
• The fan must be installed for proper airflow direction. Airflow through
2.
Install and tighten the four fan retaining screws with washers.
3.
Connect the fan wiring harness to the fan.
4.
Power up the system. (See
5.
Make sure that left side fans are moving air into system and the right side fans are
pushing air out of the system.
FORTUS 360mc/400mc Service Manual
system is from left to right as viewed from the front. Note direction of
airflow arrow on fan. Left side fan airflow is "into" the system; right side
fan airflow is "out" of the system.
Figure 5-10: Cooling Fan Air Direction
Fan Rotation
"System Power Up" on page
Air Flow
Direction
5-9.)
5-22