Removing Electrical Power - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

Warning: Always wear safety gloves and long sleeves when working in the
oven, with the head, or liquefier tips. these components can get very hot.

Removing Electrical Power

Any time service is being performed on the Fortus360mc/400mc, AC power must be
removed to the system. Perform the system shutdown sequence on the system before
removing power to the system.
Make sure the main breakers at the facility site are in their OFF position before preceding to
remove any electrical panels.
Warning: Make sure AC power is removed from the system. Voltage
of 230V AC is present and can be lethal.
Any time service is being performed on the Fortus360mc/400mc system, especially the
electrical panel where high voltage power is present, the incoming power should be locked
out to prevent someone else from inadvertently energizing the electrical system.
When line voltage is removed from the system, a UPS (Uninterruptible Power Supply) is
designed to provide power to some components in the of the system. Make sure to manually
turn off the UPS when servicing the system.
Warning: Make sure the UPS is manually turned off and not
powering components in the system.
Procedure
• Power down the system and turn Off the power. (See
8.)
FORTUS 360mc/400mc Service Manual
"System Power Down" on page 5-
1-5