And Y Belt Tension Settings - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

D.
X and Y Belt Tension Settings
Titan X Belt
Titan Y Belt
Vantage X Belt
Vantage Y Belt
FORTUS 360mc/400mc Service Manual
Table 10-6: PPU Part Dimension Limits
Dimension
Limits
X1
5.5 inches ± 0.0057 (139.7 mm ± 0.145)
Y1
5.0 inches ± 0.005 (127 mm ± 0.127)
X2 and Y2
3.0 inches ± 0.005 (76.2 mm ± 0.127)
X3 and Y3
1.0 inches ± 0.005 (25.4 mm ± 0.127)
Re-run Linear Compensation procedure for systems that fail this
test.
• PPU values must be reset before building the PPU part.
Table 10-7: X and Y Belt Tension Settings
85° (ABSi
ABS-M30
Room Temp
ABS-M30i)
-110 to -120
-85 to -95
-95 to -105
-70 to -80
-80 to -90
-65 to -75
-75 to -85
-55 to -65
110°C
145°C
(PC-ABS)
(PC)
-80 to -90
-70 to -80
-65 to -75
-55 to -65
-60 to -70
-45 to -55
-50 to -60
-40 to -50
225°C
(PPSF)
-60 to -70
-45 to -55
NA
NA
10-36