Operation: Condition; Odor/Burning - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

5.
Encased tip or liquefier block
Build sheet lost Vacuum. See
Part curled or part overfillZ
Z zero calibration failed
Head heater block run away
Tip weld broke
A.
B.
C.
D.
E.
F.
6.
Waterworks LOE issues
• WW tends to plug at the Liquefier inlet while other materials plug at the
• WW plugs can usually be cleaned out by blocking the head blower air for
• There are some unique issues with WW since it is more brittle and tends

Operation: Condition

Odor/Burning

An odor will occur when heating to PPSF temperatures. Lower temperature material stuck in
the oven will burn at PPSF temperatures causing an odor.
• Check head liquefiers with external thermometer. If external thermometer
temperature reading on liquefier does not match UI temperature for liquefier, replace
the head.
FORTUS 360mc/400mc Service Manual
"Vacuum" on page
Verify the correct tips were used.
Check tip-to-tip calibration.
Check platen level using Measure Flatness in the Maintenance
menu.
Check if tip wiper and brush assembly is set too high or ineffective
because of material buildup.
Check CFG file for temperature issues.
Check for correct tip installation.
tip.
one minute, and then purging the liquefier with the head buttons.
to break and dust up more. This means issues with the material delivery
system such as worn tubes, fragments of material or dust in the "Y" block
or canister drive blocks and old motors will be more likely with WW
material.
7-8.
7-29