Platen Vacuum Screen; Vacuum Screen Removal; Vacuum Screen Installation - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

Platen Vacuum Screen

Vacuum Screen Removal

Tools and Materials Required
• Small standard screwdriver
Procedure
1.
Use a small screwdriver to pry the retaining ring out of the platen. Discard the retaining
ring.
2.
Remove the screen.
Figure 5-48: Vacuum Screen Retaining Ring Removal

Vacuum Screen Installation

Tools and Materials Required
• 11/16-inch socket
Procedure
1.
Insert an undamaged screen into position in the platen.
2.
Place the retaining ring into the platen with the concave side up.
Retaining Ring
3.
Use a socket to push the retaining ring into the platen. Make sure the retaining ring is
secure in the platen.
FORTUS 360mc/400mc Service Manual
Use care not to damage the platen during removal of the retaining
ring.
Platen
Screen
Carefully Pry the
Retaining Ring from
the Platen
(
)
Figure 5-48