Head Cooling Fan

Purpose
1.
Prevents filament from softening before entering the tip
Figure 2-2: Filament Path from Drive Wheels to Liquefier
Drive Wheels
Filament must
remain solid in
this area.
Tip
Flange Area
Liquefier
Heater Block
Heater Block
• Filament serves two purposes within the system: in a liquefied state, it is
• Filament must remain solid from the point at which it leaves the drive
• The Head Cooling Fan directs cooling air to the drive wheel and tip flange
FORTUS 360mc/400mc Service Manual
extruded to build models; in a solid state, it is used to push softened
filament through the modeling tip.
wheels until it is inside the tip. If the filament softens too early, filament
mis-feed will occur.
area. This allows the tip to reach extruding temperature while filament
entering flange remains solid.
(Figure
2-2).