Z Guide Rod/Pillow Block Installation

Tools and Materials Required
• 9/64-inch hex key
• 3/16-inch hex key
• 5/32-inch hex key
• Krytox grease
Procedure
Caution: Do not remove plastic plug from the pillow block/bearing
assembly. It is used to retain the bearing rollers.
If a guide rod is replaced, the pillow blocks must be replaced as
well. Pillow blocks may be replaced individually.
1.
Install the pillow block/bearing assemblies onto the guide rods.
• Orient the pillow blocks so the grease fittings are at the outside of the
• Slide the two pillow blocks on the guide rod. This will push out the large
2.
Install the rod end supports onto each end of the guide rod.
All Grease Fittings
Must Face Away from
the Lead Screw
Rod End Supports
FORTUS 360mc/400mc Service Manual
system and a way from the lead screw.
plastic plugs.
Figure 5-44: Lower Z Stage Hardware
Lead Screw
Pillow Block
End Clamp Screws