Z Homing Switch Adjustment

Tools and Materials Required
• 0.010-inch (0.250 mm) shim
• 7/64-inch hex key
Procedure
1.
Remove the upper right side panel. (See
2.
Move the Z Stage to the bottom of the build envelope (Operator Control > Move Head/
Stage > Move Z Stage to Bottom).
3.
Open the oven door to disable the servo motors.
4.
Manually lower the Z Stage until the Z Stage End Plates rest on the lower hard stops.
5.
Loosen the switch bracket mounting screws using a 7/64-inch hex key. (See
on page
6-35.)
6.
Place a 0.010-inch (0.250 mm) shim between the switch roller and the switch body.
Z Stage End Plate
Switch must
actuate along
angled area of
the end plate
after adjustment.
7.
Position the switch mounting bracket so there is a light drag on the shim as the shim is
moved back and forth between the roller and the switch body.
8.
Tighten the switch bracket mounting screws.
9.
Use the shim to re-check the adjustment and readjust if necessary.
FORTUS 360mc/400mc Service Manual
Figure 6-25: Z Homing Switch Adjustment
"Panel Removal" on page
Z Home Switch
5-6.)
Figure 6-25
Slide shim between the
roller and switch body.
Switch Mount
Switch bracket
mounting screws
6-35