Belt Tension Gauge Setup
Tools and Materials Required
• Belt tension gauge
• 7/64-inch hex key
Procedure
1.
Insert the Zero Gauge Block into the Belt Tension Gauge fixture
2.
Adjust the gauge position in the fixture so the small dial is at 5 and the large hand is at
the top of the gauge. Tighten the clamp screw (7/64-inch hex key) to hold the gauge in
place. Do not over tighten the clamp screw.
3.
Rotate the dial face to zero the large gauge.
Adjustment Screw
Zero Gauge Block
FORTUS 360mc/400mc Service Manual
Figure 6-15: Tension Gauge Zero Setting
6-23