Error Messages; Ui Messages - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

Error Messages

UI Messages

UI Message
Need more Model Material--Need more
Support
Material--Need all four (4) canisters
CANNOT AUTO CALIBRATE
CALIBRATION SENSOR WRONG
ERROR 4 – Z Limit Switch - Z limit switch was
not encountered during autohome.
ERROR 5 – Home gantry - motion control
board stopped responding during autohome
find Z.
ERROR 6 – Not Homed - Autohome was not
performed or failed before the Auto Z
operation.
ERROR 7 – Not at Temp - head or oven temp.
would not stabilize at correct operating
temp.
ERROR 8 – Can't Set Torque - Z limit switch
was not encountered during autohome.
ERROR 9 – Sheet Not Reached - tip did not
encounter friction to indicate the sheet was
reached. Missing sheet most likely cause.
ERROR 10 – Sheet Too Thick - tip encountered
friction at pre-position level.
ERROR 17 – Following error in Z
FORTUS 360mc/400mc Service Manual
Table 7-2: UI Messages
Solution
Verify that all active canisters are installed.
Check cone sensor switch circuit for open
connection (Cone senor switch input on MIO
board).
"Autohome XYZ failed" on page 7-8
"Autohome XYZ failed" on page 7-8
Perform Autohome.
"AutoCal tip failed" on page 7-9
"Autohome XYZ failed" on page 7-8
Install sheet.
Check the sheet thickness. Also refer to:
"Operation: Failure" on page 7-22
"Part build stopped" on page 7-15
Check upper hard stop.
.
.
.
.
.
.
7-30