Y-Axis Guide Rod Assembly
Caution: X-axis guide rods are replaced as an assembly. an assembly
consists of the X-axis guide rods, support rails and pillow blocks.
The Y-axis guide rod assemblies are replaced in pairs. never replace
only one assembly.
Y-Axis Guide Rod Assembly Removal
Tools and Materials Required
• Set of basic service tools.
Prerequisite Procedures
• Remove Y bridge. (See
Procedure
1.
Turn the Y bridge upside down.
2.
Remove the Air Deflector - loosen and remove 4 retaining screws (7/64-inch hex key).
(Figure
10-8)
3.
Remove the X-axis heat shield - loosen and remove 4 retaining screws (5/32-inch hex
key).
FORTUS 360mc/400mc Service Manual
"Y Bridge Removal" on page
Figure 10-8: Air Deflector and X-Axis Heat Shield
10-15.)
10-22