Tip Sensor/Tip Sensor Cable; Tip Sensor/Cable Removal - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

Tip Sensor/Tip Sensor Cable

Tip Sensor/Cable Removal

Tools and Materials Required
• 7/64-inch hex key
• 5/32-inch hex key
Procedure
Access the tip sensor through the front door of the system.
1.
Position the Z stage to the approximate mid-travel position.
2.
Power down the system. (See
3.
Remove the two tip sensor mount screws from the right underside of the platen (5/32-
inch hex key).
4.
Remove the terminal contact screw (7/64-inch hex key) that attaches the tip sensor cable
to the sensor.
FORTUS 360mc/400mc Service Manual
"System Power Down" on page
Figure 5-76: Tip Sensor Replacement
Terminal Connection
Screws
5-8.)
Route the Wire Through
the Hole in the Body
of the Sensor
Cable Clamp
Route Cable Through
the Back of the Oven
5-109