Component Adjustment; Tip Wipe Height Adjustment - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

Component Adjustment

Tip Wipe Height Adjustment

An improperly adjusted tip wipe height can cause decreased tip life,
premature wear of the tip shield, and part quality degradation issues.
Tools and Materials Required
• Set of basic service tools
Prerequisite Procedures
1.
Lower the Z stage to the bottom half of the oven.
2.
Allow oven to cool to room temperature.
3.
Install model and support tips. (See
Procedure
For Titan/Vantage:
1.
Manually move the head so that the model tip is directly above its tip wipe brush.
2.
Check the height adjustment of the tip wipe - the tip should be lightly touching the wiper
brush.
3.
Power up the system. (See
4.
Stabilize the oven temperature at 145°C.
• The vertical position of the tip wipe assembly is affected by oven
5.
If necessary, adjust the tip wipe height.
A.
FORTUS 360mc/400mc Service Manual
"System Power Down/Power Up" on page
temperature.
For models with a Hinged Waste Chute Door (Titan Only)
Figure 10-16 on page
a.
Remove the waste chute door assembly.
• Open the waste chute door.
• Loosen and remove the 4 waste chute door assembly
mounting screws.
"Liquefier Tip Installation" on page
10-39.
5-18.)