Computer Installation

Tools and Materials Required
• Set of basic service tools
• Computer, PN 105607-XXXX.
Procedure
1.
Properly position the Computer in the system.
A.
B.
2.
Tighten four mounting screws.
3.
Attach power cord and interface cables to the Computer.
4.
Verify/Correct the Z home Delta parameter.
• Power up the system. (See
• Load the controller code. (See
• Perform an Autohome XYZ -
• Select
• Verify/correct the Z home Delta parameter.
• The current Z Delta is displayed on the operator panel.
• Nominal values are between 16.0 and 16.5.
• If the displayed value is out of range, modify inputs to achieve a value of
5.
Perform Auto Z Zero calibration. (See
For Titan/Vantage:
1.
Check the PPU Values. (See
2.
Perform Tip to Tip calibration. (See
39.)
3.
Check the purge position. (See
FORTUS 360mc/400mc Service Manual
Place wide area of computer keyhole slot over mounting screws.
Slide computer forward for full travel of slot.
8.)
20.)
AutoHome
XYZ.
• At completion of Autohome XYZ, the Z stage will be at the Z
Home position.
Operator Control > Calibrate > Set Z Stage Zero >
Modify Current Z
16.4.
"Linear Compensation" on page
"Tip Sensor Location/Setting Position" on page 6-
"Air Pressure and Air Flow Adjustment" on page
"System Power Down/Power Up" on page 5-
"Upgrade Controller Software" on page 3-
Operator Control > Calibrate >
Zero.
"Z Zero Calibrations" on page
6-3.)
10-33.)
6-34.)
10-31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortus 400mc

Table of Contents