24/48 Volt Power Supply

24/48 Volt Power Supply Removal

Tools and Materials Required
• #2 Phillips screwdriver
Procedure
1.
Power down the system. (See
2.
Remove the lower back panel. (See
3.
Loosen the two clamp screws for the UPS/power supply tray. (See
82.)
4.
Carefully slide the tray out of the lower bay until it reaches the end of its travel.
5.
Label and remove all wiring connections from the 24/48 volt power supply. (See
Figure 5-54 on page
6.
Remove four 24/48 volt power supply mounting screws (#2 Phillips screwdriver).
7.
Carefully lift the 24/48 volt power supply from the system.
FORTUS 360mc/400mc Service Manual
"System Power Down" on page
"Panel Removal" on page
5-83.)
5-8.)
5-6.)
Figure 5-53 on page 5-
5-81