Internal Air Components
Internal Vacuum Pump
Internal Vacuum Pump Removal
Tools and Materials
• 7/16-inch wrench open end wrench
Procedure
1.
Power down the system. (See
2.
Remove the upper and lower right side panels. (See
3.
Disconnect the electrical harness from the pump.
4.
Disconnect the vacuum tube at the pump quick release fittings.
5.
Remove four vacuum pump mounting nuts (7/16-inch wrench open end wrench) from
the underside of the mounting bracket.
6.
Remove the pump from the system.
Vacuum Tube
Connection
FORTUS 360mc/400mc Service Manual
"System Power Down" on page
Figure 5-82: Vacuum Pump
Vacuum Pump
5-8.)
"Panel Removal" on page
Electrical
Connector
Mounting Nuts
(4X)
5-6.)