And Y Motor Installation - Stratasys FORTUS 360mc Service Manual

3d production system
Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

X and Y Motor Installation
Tools and Materials Required
• 5/32-inch hex key
• Replacement cable ties
Procedure
1.
Install motor into the mount making sure the motor fits flush in the mount.
2.
Install and tighten motor mount screws.
3.
Route the motor cables along the system frame in the same location as the old cables were
located. Remove slack and secure the cables to the system frame using cable ties at the
wire tie standoffs.
4.
Plug motor cables into MIO board. Make sure connections are secure.
5.
Verify proper routing of the belts and reattach the removed belt tensioners to the mount
blocks. (See
"X and Y Belt Installation" on page
6.
Install the gantry fan bank, tighten the mounting screws using a
5/32-inch hex key and connect the electrical connectors to the fans.
7.
Install the top panels. (See
8.
Adjust belt tension for X and Y drive belts. (See
9.
Power up the system. (See
10.
Load material.
FORTUS 360mc/400mc Service Manual
Figure 5-17: Motor Cable Orientation
X and Y Motor Cable
Connectors Must Face
Toward Front of System
"Panel Installation" on page
"System Power Up" on page
Front of System
5-26.)
5-7.)
"XY Gantry Belt Tension" on page
5-9.)
6-24.)
5-32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortus 400mc

Table of Contents