Goodrive100-PV Series Solar Pump Inverter
Function
code
P00.15
parameter
autotuning
Function
P00.18
parameter

P01 group Start and stop control

Function
code
P01.08
Stop mode
Name
Do not change the setting of the parameter
because reverse running is not allowed in
water pump application scenarios.
2: Disable reverse running. It can be used in
some special scenarios where reverse
running is disallowed.
0: No operation
1: Rotation autotuning
Comprehensive
autotuning. It is recommended to use
rotation autotuning when high control
Motor
accuracy is needed.
2: Static autotuning
Used in scenarios where the motor cannot
be disconnected from load.
3: Static autotuning 2
Empty-load current and mutual inductance
are not autotuned.
0: No operation
1: Restore default values
2: Clear fault records
Note:
After the selected operation is performed,
the function code is automatically restored
restore
to 0.
Restoring the default values may delete the
user password. Exercise caution before
using this function.
Name
0: Decelerate to stop. When a stop
command takes effect, the inverter lowers
output frequency based on the DEC mode
and the defined DEC time; when the
frequency drops to 0Hz, the inverter stops.
Description
motor
Description
-25-
Function parameter list
Default Modify
parameter
0
0
Default Modify
0

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive100-PV Series and is the answer not in the manual?

Questions and answers

Hamse Ismael
March 9, 2025

I want to connect a low water level sensor to GD100-PV invt how it supposed to do

2 comments:
Mr. Anderson
March 9, 2025

The low water level sensor should be connected to the INVT Goodrive100-PV Series inverter at the designated terminal. Based on the standard wiring diagram:

1. Identify the low water level switch terminals.
2. Connect the common terminal of the sensor to the COM terminal on the inverter.
3. Connect the sensor output to the appropriate input terminal (e.g., S1 or S4) on the inverter.
4. Ensure wiring is secure and correctly configured according to the installation guidelines.

This setup allows the inverter to receive signals from the low water level sensor and respond accordingly.

This answer is automatically generated