Parts Replacement and Cleaning > Periodic Replacing Parts, Durable Parts, Cleaning Parts > Cleaning Fixing Feed Unit (2 hundred thousand sheet)
9) Blow off the dirt around the secondary transfer static eliminator with using a blower.
Static eliminator
11) Clean the surface [A] of the pre-fixing feed belt with lint-free paper moistened with alcohol in direction [B] and wipe-off the dirt accumulated on the edge area by moving it in direction [C]. Then, rotate
the belt pulley and clean the all surface [A] of the pre-fixing feed belt.
Caution :
Be careful not to displace the pre-fixing
feed belt.
4
Parts Replacement and Cleaning > Periodic Replacing Parts, Durable Parts, Cleaning Parts > Cleaning Fixing Feed Unit (2 hundred thousand sheet)
10) Carefully remove the other paper to prevent the dirt from spreading.