Canon imagePRESS 1135 Series Service Manual page 797

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

Detail
Code
Location
Item
Code
E584 8003
02
Title
Error in the stack delivery lower/shutter motor
Description
The shutter does not come off the shutter close detection
of detection
sensor.
Measures
1. Check the connector of the shutter close detection sensor
(S148), and replace the sensor if necessary.
2. Check the connector of the stack delivery lower/shutter
motor (M122), and replace the motor if necessary.
3. Replace the finisher controller PCB.
E584 8004
02
Title
Error in the stack delivery lower/shutter motor
Description
The shutter close detection sensor does not detect the
of detection
shutter.
Measures
1. Check the connector of the shutter close detection sensor
(S148), and replace the sensor if necessary.
2. Check the connector of the stack delivery lower/shutter
motor (M122), and replace the motor if necessary.
3. Replace the finisher controller PCB.
E585 8001
02
Title
Stack retainer motor error
Description
HP sensor does not turn ON even though 250 msec has
of detection
passed since the start of operation.
Measures
1. Check the connector of the stack retainer HP sensor.
2. Check the connector of the stack retainer motor.
3. Replace the stack retainer HP sensor.
4. Replace the stack retainer motor.
5. Replace the finisher controller PCB.
E585 8002
02
Title
Stack retainer motor error
Description
HP sensor does not turn OFF even though 250 msec has
of detection
passed since the start of operation.
Measures
1. Check the connector of the stack retainer HP sensor.
2. Check the connector of the stack retainer motor.
3. Replace the stack retainer HP sensor.
4. Replace the stack retainer motor.
5. Replace the finisher controller PCB.
E586 8001
51
Title
Error in lock of decurler shift motor (M11) of the stacker
Description
Decurler shift HP sensor (S14) failed to be OFF even though
of detection
specified period of time has passed in the case of adjusting
decurler pressure
Measures
1. Check the connector of the decurler shift HP sensor (S14),
and replace the sensor if necessary.
2. Replace the decurler shift motor (M11).
3. Replace the master controller PCB.
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
Detail
Code
Location
Item
Code
E586 8001
52
Title
Error in lock of decurler shift motor (M11) of the 2nd stacker
Description
Decurler shift HP sensor (S14) failed to be OFF even though
of detection
specified period of time has passed in the case of adjusting
decurler pressure
Measures
1. Check the connector of the decurler shift HP sensor (S14),
and replace the sensor if necessary.
2. Replace the decurler shift motor (M11).
3. Replace the master controller PCB.
E586 8002
51
Title
Error in lock of decurler shift motor (M11) of the stacker
Description
Decurler shift HP sensor (S14) failed to be ON even though
of detection
specified period of time has passed in the case of adjusting
decurler pressure
Measures
1. Replace the decurler shift HP sensor (S14).
2. Replace the decurler shift motor (M11).
3. Replace the master controller PCB.
E586 8002
52
Title
Error in lock of decurler shift motor (M11) of the 2nd stacker
Description
Decurler shift HP sensor (S14) failed to be ON even though
of detection
specified period of time has passed in the case of adjusting
decurler pressure
Measures
1. Replace the decurler shift HP sensor (S14).
2. Replace the decurler shift motor (M11).
3. Replace the master controller PCB.
E586 8011
51
Title
Error in lock of decurler feed motor (M14) of the stacker
Description
The lock signal was monitored 1.5 sec after the motor has
of detection
started to be driven, and locking state continued for specified
period of time.
Measures
1. Replace the decurler feed motor (M14).
2. Replace the master controller PCB.
E586 8011
52
Title
Error in lock of decurler feed motor (M14) of the 2nd stacker
Description
The lock signal was monitored 1.5 sec after the motor has
of detection
started to be driven, and locking state continued for specified
period of time.
Measures
1. Replace the decurler feed motor (M14).
2. Replace the master controller PCB.
E587 0001
51
Title
Error in lock of cooling fan 1 (FAN1) of the stacker
Description
Lock signal has been ON continuously for specified period of
of detection
time
Measures
1. Replace the cooling fan 1 (FAN1).
2. Replace the master controller PCB.
E587 0001
52
Title
Error in lock of cooling fan 1 (FAN1) of the 2nd stacker
Description
Lock signal has been ON continuously for specified period of
of detection
time
Measures
1. Replace the cooling fan 1 (FAN1).
2. Replace the master controller PCB.
7-65