Location Code
Description
30
- 0015 Leakage in secondary
transfer static eliminator
high-voltage
30
- 0021 ATVC error in primary
transfer
30
- 0025 ATVC error in primary
transfer
30
- 0031 ATVC error in secondary
transfer
30
- 0032 ATVC error in secondary
transfer
30
- 0033 ACVC error in ITB cleaner
downstream
30
- 0034 ACVC error in ITB cleaner
downstream
30
- 0035 ACVC error in ITB cleaner
upstream
30
- 0036 ACVC error in ITB cleaner
upstream
31
- 0006 HDD failure when equipped
with the mirroring function
33
- 0010 Stream reading fan alarm
33
- 0022 Read motor / Delivery
motor fan alarm
33
- 0023 Back side scanner (DADF)
cooling fan 1 alarm
33
- 0025 Surface scanner (Reader)
cooling fan 1 alarm
34
- 0001 Fine adjustment of auto
registration
34
- 0002 Fine adjustment of auto
registration
34
- 0004 Fine adjustment of auto
registration
34
- 0005 Fine adjustment of auto
registration
34
- 0006 Fine adjustment of auto
registration
7
Error Code > Alarm Code > Alarm Code Details
Detailed description
Current leakage is detected.
Life is about to end and upper limit is exceeded.
Life is about to end and lower limit is exceeded.
Life is about to end and upper limit is exceeded.
Life is about to end and lower limit is exceeded.
Life is about to end and upper limit is exceeded.
Life is about to end and lower limit is exceeded.
Life is about to end and upper limit is exceeded.
Life is about to end and lower limit is exceeded.
When it is equipped with the mirroring function,
HDD is broken.
Set: When fan error is detected at the end of job.
Reset: When the fan normally finishes at the end of
job.
Set: When fan error is detected during job
processing.
Reset: When the fan normally finishes at the end of
job.
Set: When fan error is detected during job
processing.
Reset: When the fan normally works during job
processing.
Set: When fan error is detected during job
processing.
Reset: When the fan normally works during job
processing.
Front/rear patch cannot be read.
Correction value per skew adjustment correction
exceeds the limit.
Correction value per writing correction in sub
scanning exceeds the limit.
Sum of correction values of writing correction in sub
scanning exceeds the total limit.
Correction value per writing correction in main
scanning exceeds the limit.
7
Error Code > Alarm Code > Alarm Code Details
Location Code
Description
34
- 0008 Fine adjustment of auto
registration
34
- 0009 Fine adjustment of auto
registration
34
- 0101 Adjustment of active
registration
34
- 0102 Adjustment of active
registration
34
- 0103 Adjustment of active
registration
34
- 0205 Coarse adjustment of auto
registration
34
- 0209 Coarse adjustment of auto
registration
34
- 0211 Coarse adjustment of auto
registration
34
- 0401 Lead edge patch detection
area at adjustment of
registration detection light
intencity
34
- 0412 Center registration sensor
area at adjustment of
registration detection light
intencity
37
- 0001 For R&D
37
- 0002 For R&D
37
- 0003 For R&D
37
- 0004 For R&D
37
- 0005 For R&D
37
- 0006 For R&D
37
- 0007 For R&D
37
- 1000 For R&D
37
- 2000 For R&D
50
- 0007 Post separation sensor is
lack of light intensity
50
- 0008 Read sensor is lack of light
intensity
7-208
Detailed description
Correction value per magnification correction in
main scanning exceeds the limit.
Sum of correction values of magnification correction
in sub scanning exceeds the total limit.
The input skew amount exceeds the acceptable
level for the Active registration area (Registration
unit).
The input horizontal registration amount exceeds
the acceptable level for the Active registration area
(Registration unit).
The input vertical registration amount exceeds the
acceptable level for the Active registration area
(Registration unit).
Sum of correction values per writing correction in
sub scanning exceeds the total limit.
Sum of correction values of magnification correction
in sub scanning exceeds the total limit.
Center patch cannot be read.
ITB gross decrease is detected.
ITB gross decrease is detected.
For R&D
For R&D
For R&D
For R&D
For R&D
For R&D
For R&D
For R&D
For R&D
Set: When the light intensity is insufficient at
adjustment.
Reset: Operation terminates normally at the next
adjustment.
Set: When the light intensity is insufficient at
adjustment.
Reset: Operation terminates normally at the next
adjustment.