Parts Replacement and Cleaning > Main Unit > Pulling Out Process Unit
6) Hold the grip, push the process unit, and fit the edge face of the process unit to the edge face of the host machine place.
Caution : Caution during process
unit storage
When pushing the process unit, if
the phase of the drum and the drum
shaft don't fit, the process unit can't
be fully pushed to the host machine.
If they don't fit, refer to the below
procedure, fit the phase of the drum
and the drum shaft, and fix it with
drum home position flag.
Caution :
When rotating the drum, be sure
to rotate it counter clockwise.
(If it is rotated clockwise, the drum
surface might get damaged).
4
Parts Replacement and Cleaning > Main Unit > Pulling Out Process Unit
Edge of sheet
Edge of sheet metal
metal on host machine
on host machine
Edge of the process unit
F-4-84
4-74
Edge of
the process
unit
F-4-83
4-74