Canon imagePRESS 1135 Series Service Manual page 977

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER> DISPLAY> DPOT
EPC-VL1
Dspl of potential VL1 at potential cntrl
Lv.1 Details
Displaying light area potential VL1 at the time of laser output (50H)
that is measured by potential control.
In normal status, it will be VL4<VL3<VL2<VL1<500 (V).
In abnormal status, this can identify an assumed cause from
potentail sensor, drum and charging assembly.
Use case
When the image density is out of the reference, check if there is fault
in potential control.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 600
Unit
V
Appropriate target value 80 to 450
Related service mode
COPIER> DISPLAY> DPOT> EPC-VL2, EPC-VL3, EPC-VL4
EPC-VL2
Dspl of potential VL2 at potential cntrl
Lv.1 Details
Displaying light area potential VL2 at the time of laser output (90H)
that is measured by potential control.
In normal status, it will be VL4<VL3<VL2<VL1<500 (V).
In abnormal status, this can identify an assumed cause from
potentail sensor, drum and charging assembly.
Use case
When the image density is out of the reference, check if there is fault
in potential control.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 600
Unit
V
Appropriate target value 80 to 450
Related service mode
COPIER> DISPLAY> DPOT> EPC-VL1, EPC-VL3, EPC-VL4
EPC-VL3
Dspl of potential VL3 at potential cntrl
Lv.1 Details
Displaying light area potential VL2 at the time of laser output (C0H)
that is measured by potential control.
In normal status, it will be VL4<VL3<VL2<VL1<500 (V).
In abnormal status, this can identify an assumed cause from
potentail sensor, drum and charging assembly.
Use case
When the image density is out of the reference, check if there is fault
in potential control.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 600
Unit
V
Appropriate target value 80 to 450
Related service mode
COPIER> DISPLAY> DPOT> EPC-VL1, EPC-VL2, EPC-VL4
8
Service Mode > COPIER > DISPLAY (Status Display Mode) > DPOT
8
Service Mode > COPIER > DISPLAY (Status Display Mode) > DPOT
COPIER> DISPLAY> DPOT
EPC-VL4
Dspl of potential VL4 at potential cntrl
Lv.1 Details
Displaying light area potential VL2 at the time of laser output (F0H)
that is measured by potential control.
In normal status, it will be VL4<VL3<VL2<VL1<500 (V).
In abnormal status, this can identify an assumed cause from
potentail sensor, drum and charging assembly.
Use case
When the image density is out of the reference, check if there is fault
in potential control.
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to 600
Unit
V
Appropriate target value 80 to 450
Related service mode
COPIER> DISPLAY> DPOT> EPC-VL1, EPC-VL2, EPC-VL3
8-34
T-8-9
8-34

Hide quick links:

Advertisement

Table of Contents
loading