Here is the MeapBack upload procedure as an example.
1) Start the machine in safe mode. (While pressing 2 + 8, turn ON the main power switch.)
2) Start up the SST.
3) Select the model and the type of system software ('Single') ; then, check the network
settings, and click [START].
Service Support Tool DLM0 (Ver. X.XX E)
Interface
Network
IP Address
172.16.1.100
Register
Remove
Target Selection
CONTROL
Export Firm Selection
Select the target.
Click a button to execute.
Click the interface and click the [START]
MFP
button.
iPR1135
iPR1135
CONNECT
MFP
Single
R egi s t er Fi rm war e
USB
D el et e Fi rm war e
Del ete B a c k up Dat a
USB
S y s te m Ma nag emen t
c:
START
S tar t A s s i s t Mo de
EXIT
4) Click [Upload Data].
ServiceSupportTool DLM10 (Ver. X.XX E)
SelectableFirmware
Control
Select the firmware to be downloaded,
Click the button of the task to be
then click the [Start] button.
executed.
SelectableFirmware
iPR1135
Download Firmware
ASR
BROWSER
DCON
HELP
LANGUAGE
MEAPCONT
MEDIA
RCON
Restore Backup System
RUI
SYSTEM
TTS
WebDAV
iRZZZZ
KEY
SDICT
Return to Main Menu
6
Troubleshooting > Version Upgrade > Uploading and Downloading Backup Data > Uploading Procedure
Select the model
ALL
Type of system software
172.16.1.100
iPR1135
SAFE
C l e a r
iPR1135
SYSTEM
Hold
USenXXXXM
Backup
USenXXXXW
RUI
XXenXXXX
MEAPCONT
Upload Data
XXxxXXXX
LANGUAGE
XXenXXXX
Download Data
XXjaXXXX
SDICT
XXjaXXXX
Format HDD
Start
Shutdown
F-6-91
6
Troubleshooting > Version Upgrade > Uploading and Downloading Backup Data > Uploading Procedure
5) Select 'MeapBack.bin', and click [Start].
ServiceSupportTool DLM10 (Ver. X.XX E)
FileSave
File Name
Memo
c:
6) Enter the file name to save and memo if needed, and then click [Save].
ServiceSupportTool DLM10 (Ver. X.XX E)
F-6-90
FileSave
Enter desired file name, then click the
[Save] button.
File Name
MeapBack.bin
Memo
Memo
c:
7) Click [OK].
172.16.1.100
iPR1135
SAFE
C l e a r
Control
SelectableDate
Click the button of the task to be
Select the data to be uploaded, then click
the [Start] button.
executed.
MeapBack.bin
Download Firmware
SramImg.bin
Upload Data
Download Data
backup of meap
Restore Backup System
Format HDD
Start
Cancel
Return to Main Menu
F-6-92
172.16.1.100
iPR1135
SAFE
C l e a r
SelectableDate
Control
Click the button of the task to be
Uploading complete
executed.
MeapBack.bin
Download Firmware
SramImg.bin
Upload Data
Download Data
backup of meap
Restore Backup System
Format HDD
Save
Discard
Return to Main Menu
F-6-93