4
Parts Replacement and Cleaning > Main Unit > Pulling Out Process Unit
2) Remove the 2 screws to remove the ITB positioning plate.
ITB positioning plate
x2
4) Remove the 4 screws.
5) Hold the grip and pull out the process unit toward front.
x4
4
Parts Replacement and Cleaning > Main Unit > Pulling Out Process Unit
3) Remove the drum HP flag.
• 1 stepped screw
• 1 spring
F-4-80
F-4-81
Process unit
F-4-82
4-73
4-73