Canon imagePRESS 1135 Series Service Manual page 703

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

1)
Status of
reception(sample)
- - - Download Mode - - -
[ iR2270i-JPjaxxxx-MN.dsh ] - - - - xx%
System
Software
2)
HDD
System
3)
Writing takes place.
Software
<<<<< download shell >>>>>
Temporary
[ SYSTEM JPja-m ] - - - -
Upgrading complete
[ SYSTEM ZZ ] - - - - - - -
Upgrading complete
[ SYSTEM JPja-w ] - - - -
Upgrading complete
storage area
[ SYSTEM ZZ ] - - - - - - -
Upgrading complete
[ FONT F ] - - - - - - - - - -
Upgrading complete
[ FONT G ] - - - - - - - - - -
Upgrading complete
+++ Switch OFF the power then ON. +++
System area
BOOT領域
FLASH
ROM
There are 2 ways to download the system software.
• Batch download
To download various system software collectively
The system software (combination) that will be downloaded with batch download is stated
in the batch download information file ("ALL") which is stored on the system CD. Register
the system software in SST to enable the batch download function.
• Individual download
To download the selected system software individually
6
Troubleshooting > Version Upgrade > Outline > Points to Note at Time of Downloading
The system software is downloaded.
- - - Download Mode - - -
[ iR2270i-JPjaxxxx-MN.dsh ] - - - - - - - - - -
Complete
[ iR2270iM-JPjaxxxx-1F77-MN.PRG ] - - - -
Complete
[ iR2270iM-ZZjaxxxx-49AD.PRG ] - - - - - - -
Complete
[ iR2270iW-JPjaxxxx-5C16-MN.PRG ] - - - -
Complete
[ iR2270iW-ZZjaxxxx-A825.PRG ] - - - - - - -
Complete
[ iR2270iF-JPjaxxxx-DE96-ICC.PRG ] - - - -
Complete
[ iR2270iW-ZZjaxxxx-A825.PRG ] - - - - - - -
Complete
[ iR2270iG-JPjaxxxx-EC30-ICC.PRG ] - - - -
Complete
HDD
System
Software
Temporary
storage area
The main power switch is turned off and then on.
4)
The main power switch is turned off and then on.
5)
The machine starts up using the new version.
6
Troubleshooting > Version Upgrade > Outline > Points to Note at Time of Downloading
■ Points to Note at Time of Downloading
CAUTION : Do Not Turn Off the Power During Download / Write Operation
Do not turn OFF the power while the system software is being downloaded or written.
The machine may fail to start when the power is turned ON.
If the power cannot be turned ON, try to start it in safe mode (press 2 + 8
simultaneously).
If the machine starts in safe mode, download the system software again. If not, replace
HDD and download the system software.
CAUTION :
It is recommended to download DCON / RCON in normal mode.
DCON / RCON may be downloaded in either normal mode or safe mode. However,
if done in safe mode, the version information of DCON/RCDON will not be obtained.
In this case, DCON / RCON on HDD is always overwritten by DCON / RCON on SST
regardless of versions; thus it may be downgraded.
F-6-41
6-36
6-36